References
-
Hancuh, M. et al. Typhoid fever Surveillance, incidence Estimates, and progress toward typhoid conjugate vaccine Introduction — Worldwide, 2018–2022. Morb Mortal. Wkly. Rep. 72 (7), 171–176 (2023).
-
Chen, J. et al. Taking on typhoid: eliminating typhoid fever as a global health problem. Open. Forum Infect. Dis. 10 (1), S74–81 (2023).
-
Diwaker, A. et al. Enteric fever and the diagnostic tools: defining the accuracy. Front. Bacteriol. 3 (1), 1–11 (2024).
-
Geteneh, A., Tadesse, S., Biset, S., Girma, L. & Fissiha, P. Rapid stool antigenic test for typhoid fever among suspected Cases, Northeast, Ethiopia. Sci. Rep. 13 (1), 649 (2023).
-
Frempong, S. N., King, N. & Sagoo, G. S. The Cost-Effectiveness of using rapid diagnostic tests for the diagnosis of typhoid fever in patients with suspected typhoid fever: A systematic review. Expert Rev. Pharmacoecon Outcomes Res. 22 (3), 391–397 (2022).
-
Saini, V. & Duggal, N. Comparison of rapid tests (Antigen vs. Antibody) for the diagnosis of typhoid in the first and second weeks of fever. J. Fam Med. Prim. Care. 11 (7), 3730–3734 (2022).
-
Wijedoru, L., Mallett, S. & Parry, C. M. Rapid diagnostic tests for typhoid and paratyphoid (Enteric) fever. Cochrane Database Syst. Rev. 2017 (5), 1–44 (2017).
-
Arora, P., Thorlund, K., Brenner, D. R. & Andrews, J. R. Comparative accuracy of typhoid diagnostic tools: A bayesian Latent-Class network analysis. PLoS Negl. Trop. Dis. 13 (5), e0007303 (2019).
-
Sapkota, J. et al. Diagnostics for typhoid fever: current perspectives and future outlooks for product development and access. Open. Forum Infect. Dis. 10 (1), 17–20 (2023).
-
Chen, X-F., Zhao, X. & Yang, Z. Aptasensors for the detection of infectious pathogens: design strategies and Point-Of-Care testing. Microchim. Acta. 189 (12), 443 (2022).
-
Aljohani, M. M. et al. Aptamers: potential diagnostic and therapeutic agents for blood diseases. Molecules 27 (2), 383 (2022).
-
Majdinasab, M., Badea, M. & Marty, J. L. Aptamer-Based lateral flow assays: current trends in clinical diagnostic rapid tests. Pharmaceuticals 15 (1), 90 (2022).
-
Domsicova, M., Korcekova, J., Poturnayova, A. & Breier, A. New insights into aptamers: an alternative to antibodies in the detection of molecular biomarkers. Int. J. Mol. Sci. 25 (13), 6833 (2024).
-
Omage, J. I. et al. Cancer diagnostics and early detection using electrochemical aptasensors. Micromachines 13 (4), 522 (2022).
-
Ahmad Najib, M. et al. Isolation and characterization of DNA aptamers against the HlyE antigen of Salmonella Typhi. Sci. Rep. 14 (1), 28416 (2024).
-
Aslan, Y. et al. Aptamer-Based Point-of-Care devices: emerging technologies and integration of computational methods. Biosensors 13 (5), 569 (2023).
-
Buglak, A. A., Samokhvalov, A. V., Zherdev, A. V. & Dzantiev, B. B. Methods and applications of in Silico aptamer design and modeling. Int. J. Mol. Sci. 21 (22), 8420 (2020).
-
Hianik, T. & Wang, J. Electrochemical Aptasensors – Recent achievements and perspectives. Electroanalysis 21 (11), 1223–1235 (2009).
-
Hasan, M. R. et al. Electrochemical aptasensor developed using Two-Electrode setup and Three-Electrode setup: comprising their current range in context of dengue virus determination. Biosensors 13 (1), 1 (2022).
-
Al Borhani, W., Chrouda, A., Eissa, S. & Zourob, M. Selection of a new aptamer targeting amoxicillin for utilization in a Label-Free electrochemical biosensor. Talanta 276, 126245 (2024).
-
Corbacioglu, Ş. & Aksel, G. Receiver operating characteristic curve analysis in diagnostic accuracy studies: A guide to interpreting the area under the curve value. Turkish J. Emerg. Med. 23 (4), 195 (2023).
-
Ong, E. B. B., Anthony, A. A., Ismail, A., Ismail, A. & Lim, T. S. Cloning, Expression, and purification of the Hemolysin/Cytolysin (HlyE Antigen) from Salmonella enterica serovar typhi: potential application for immunoassay development. Diagn. Microbiol. Infect. Dis. 77 (1), 87–89 (2013).
-
Manalastas-Cantos, K. et al. ATSAS 3.0: expanded functionality and new tools for Small-Angle scattering data analysis. J. Appl. Crystallogr. 54 (1), 343–355 (2021).
-
Svergun, D. I. Determination of the regularization parameter in Indirect-Transform methods using perceptual criteria. J. Appl. Crystallogr. 25 (4), 495–503 (1992).
-
Franke, D., Svergun, D. I. & DAMMIF A program for rapid Ab-Initio shape determination in Small-Angle scattering. J. Appl. Crystallogr. 42 (2), 342–346 (2009).
-
Grudinin, S., Garkavenko, M. & Kazennov, A. Pepsi-SAXS: an adaptive method for rapid and accurate computation of Small-Angle X-Ray scattering profiles. Acta Crystallogr. Sect. D Struct. Biol. 73 (5), 449–464 (2017).
-
Eberhardt, J., Santos-Martins, D., Tillack, A. F., Forli, S. & AutoDock Vina 1.2.0: new Docking Methods, expanded force Field, and python bindings. J. Chem. Inf. Model. 61 (8), 3891–3898 (2021).
-
Trott, O. & Olson, A. J. AutoDock vina: improving the speed and accuracy of Docking with a new scoring Function, efficient Optimization, and multithreading. J. Comput. Chem. 31 (2), 455–461 (2010).
-
Forli, S. et al. Computational Protein–Ligand Docking and virtual drug screening with the AutoDock suite. Nat. Protoc. 11 (5), 905–919 (2016).
-
Jo, S., Kim, T., Iyer, V. G. & Im, W. CHARMM-GUI: A Web‐Based graphical user interface for CHARMM. J. Comput. Chem. 29 (11), 1859–1865 (2008).
-
Lee, J. et al. CHARMM-GUI input generator for NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM simulations using the CHARMM36 additive force field. J. Chem. Theory Comput. 12 (1), 405–413 (2016).
-
Hess, B., Kutzner, C., van der Spoel, D. & Lindahl, E. GROMACS 4: algorithms for highly Efficient, Load-Balanced, and scalable molecular simulation. J. Chem. Theory Comput. 4 (3), 435–447 (2008).
-
Wan, H. et al. Screen-Printed gold electrode with gold nanoparticles modification for simultaneous electrochemical determination of lead and copper. Sens. Actuators B Chem. 209, 336–342 (2015).
-
Pham, M-L., Maghsoomi, S. & Brandl, M. An electrochemical aptasensor for the detection of freshwater cyanobacteria. Biosensors 14 (1), 28 (2024).
-
Gegenschatz, S. A., Chiappini, F. A., Teglia, C. M., Muñoz de la Peña, A. & Goicoechea, H. C. Binding the gap between Experiments, Statistics, and method comparison: A tutorial for computing limits of detection and quantification in univariate calibration for complex samples. Anal. Chim. Acta. 1209, 339342 (2022).
-
Jumper, J. et al. Highly accurate protein structure prediction with alphafold. Nature 596 (7873), 583–589 (2021).
-
Biesiada, M. et al. Automated RNA 3D Structure Prediction with RNAComposer. In: Methods in Molecular Biology. pp. 199–215. (2016).
-
Liang, G. et al. Application and evaluation of molecular Docking for aptamer and small molecular Interaction – A case study with Tetracycline antibiotics. Talanta 266, 124942 (2024).
-
Morozov, D. et al. The role of SAXS and molecular simulations in 3D structure Elucidation of a DNA aptamer against lung cancer. Mol. Ther. – Nucleic Acids. 25, 316–327 (2021).
-
He, H., Liu, C. & Liu, H. Model reconstruction from Small-Angle X-Ray scattering data using deep learning methods. iScience 23 (3), 100906 (2020).
-
Zambry, N. S. et al. Aptamer-Based electrochemical biosensors for the detection of salmonella: A scoping review. Diagnostics 12 (12), 3186 (2022).
-
Sande, M. G. et al. Electrochemical aptasensor for the detection of the key virulence factor YadA of yersinia Enterocolitica. Biosensors 12 (8), 614 (2022).
-
Jarczewska, M., Sokal, M., Olszewski, M. & Malinowska, E. Studies on the aptasensor miniaturization for electrochemical detection of lead ions. Biosensors 14 (2), 110 (2024).
-
Goay, Y. X. et al. Identification of five novel Salmonella Typhi-Specific genes as markers for diagnosis of typhoid fever using Single-Gene target PCR assays. Biomed. Res. Int. 2016, 1–9 (2016).
-
Rigby, J. et al. Optimized methods for detecting Salmonella Typhi in the environment using validated field Sampling, culture and confirmatory molecular approaches. J. Appl. Microbiol. 132 (2), 1503–1517 (2022).
-
Muniandy, S., Thong, K. L., Appaturi, J. N., Lai, C. W. & Leo, B. F. Electrochemical aptasensor for Salmonella detection using Nafion-doped reduced graphene oxide. Sens. Diagnostics. 1 (6), 1209–1217 (2022).
-
Antillon, M., Saad, N. J., Baker, S., Pollard, A. J. & Pitzer, V. E. The relationship between blood sample volume and diagnostic sensitivity of blood culture for typhoid and paratyphoid fever: A systematic review and Meta-Analysis. J. Infect. Dis. 218 (4), 255–267 (2018).
-
Husna, R., Kurup, C. P., Ansari, M. A., Mohd-Naim, N. F. & Ahmed, M. U. An electrochemical aptasensor based on AuNRs/AuNWs for sensitive detection of Apolipoprotein A-1 (ApoA1) from human serum. RSC Adv. 13 (6), 3890–3898 (2023).
-
Aye, N. N. S. et al. A simple graphene functionalized electrochemical aptasensor for the sensitive and selective detection of glycated albumin. Appl. Sci. 11 (21), 10315 (2021).
-
Wei, S. et al. On-Site colorimetric detection of Salmonella typhimurium. Npj Sci. Food. 6 (1), 48 (2022).
